Skip Navigation

This Article
Right arrow FREE Full Text (Print PDF) Freely available
Right arrow Comments: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Comments are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Lijuan, H.
Right arrow Articles by Harrington, P. d. B.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Lijuan, H.
Right arrow Articles by Harrington, P. d. B.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© Oxford University Press

Development of an expert system for amino acid sequence identification

Hu Lijuan , Elaine F. Saulinskas 1, Peter Johnson 2 and Peter de B. Harrington 3

Center for Intelligent Chemical Instrumentation, Ohio University Athens, OH 45701-2979, USA
1Center for Research and Technology, Department of Chemistry, Ohio University Athens, OH 45701-2979, USA
2College of Osteopathic Medicine, Clippinger Laboratories, Ohio University Athens, OH 45701-2979, USA

3To whom correspondence should be addressed

An expert system for amino acid sequence identification has been developed. The algorithm uses heuristic rules developed by human experts in protein sequencing. The system is applied to the chromatographic data of phenylthiohydantoin-amino acids acquired from an automated sequencer. The peak intensities in the current cycle are compared with those in the previous cycle, while the calibration and succeeding cycles are used as ancillary identification criteria when necessary. The retention time for each chromatographic peak in each cycle is corrected by the corresponding peak in the calibration cycle at the same run. The main improvement of our system compared with the onboard software used by the Applied Biosyste 477A Protein/Peptide Sequencer is that each peak in each cycle is assigned an identification name according to the corrected retention time to be used for the comparison with different cycles. The system was developed from analyses of ribonuclease A and evaluated by runs of four other protein samples that were not used in rule development. This paper demonstrates that rules developed by human experts can be automatically applied to sequence assignment. The expert system performed more accurately than the onboard software of the protein sequencer, in that the misidentification rates for the expert system were around 7%, whereas those for the onboard software were between 13 and 21%.


Received on April 18, 1996; accepted on June 5, 1996

Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.