Skip Navigation

Bioinformatics 2008 24(13):i407-i413; doi:10.1093/bioinformatics/btn143
This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (Print PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Google Scholar
Right arrow Articles by Wang, Y.
Right arrow Articles by Wong, S. T.C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wang, Y.
Right arrow Articles by Wong, S. T.C.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© 2008 The Author(s)
This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/2.0/uk/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

Reversible jump MCMC approach for peak identification for stroke SELDI mass spectrometry using mixture model

Yuan Wang 1,2, Xiaobo Zhou 1,*, Honghui Wang 3, King Li 1, Lixiu Yao 2 and Stephen T.C. Wong 1

1Center for Biotechnology and Informatics (CBI), The Methodist Hospital Research Institute, and Department of Radiology, The Methodist Hospital, Weill Cornell Medical College, Houston, TX 77030, USA, 2School of Electronics, Information and Electrical Engineering, Shanghai Jiao Tong University, China and 3Critical Care Medicine Department, Clinical Center, National Institutes of Health, Bethesda, MD 20892, USA

*To whom correspondence should be addressed.


   Abstract

Mass spectrometry (MS) has shown great potential in detecting disease-related biomarkers for early diagnosis of stroke. To discover potential biomarkers from large volume of noisy MS data, peak detection must be performed first. This article proposes a novel automatic peak detection method for the stroke MS data. In this method, a mixture model is proposed to model the spectrum. Bayesian approach is used to estimate parameters of the mixture model, and Markov chain Monte Carlo method is employed to perform Bayesian inference. By introducing a reversible jump method, we can automatically estimate the number of peaks in the model. Instead of separating peak detection into substeps, the proposed peak detection method can do baseline correction, denoising and peak identification simultaneously. Therefore, it minimizes the risk of introducing irrecoverable bias and errors from each substep. In addition, this peak detection method does not require a manually selected denoising threshold. Experimental results on both simulated dataset and stroke MS dataset show that the proposed peak detection method not only has the ability to detect small signal-to-noise ratio peaks, but also greatly reduces false detection rate while maintaining the same sensitivity.

Contact: XZhou{at}tmhs.org



Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.