Skip Navigation



Bioinformatics Advance Access published online on July 11, 2007

Bioinformatics, doi:10.1093/bioinformatics/btm346
This Article
Right arrow Advance Access manuscript (PDF) Freely available
Right arrow All Versions of this Article:
23/18/2441    most recent
btm346v1
Right arrow Comments: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Comments are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Harezlak, J.
Right arrow Articles by Lin, X.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Harezlak, J.
Right arrow Articles by Lin, X.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author (2007). Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

Quantitative quality-assessment techniques to compare fractionation and depletion methods in SELDI-TOF mass spectrometry experiments

Jaroslaw Harezlak a,*, Mike Wang b, David Christiani b and Xihong Lin a

a Department of Biostatistics, b Department of Environmental Health, Harvard School of Public Health 655 Huntington Ave. Boston, MA 02115

*To whom correspondence should be addressed. Dr. Jaroslaw Harezlak, E-mail: jharezla{at}hsph.harvard.edu


   Abstract

Motivation: Mass-spectrometry (MS), such as the surface-enhanced laser desorption and ionization time-of-flight (SELDI-TOF) MS, provides a potentially promising proteomic technology for biomarker discovery. An important matter for such a technology to be used routinely is its reproducibility. It is of significant interest to develop quantitative measures to evaluate the quality and reliability of different experimental methods.

Results: We compare the quality of SELDI-TOF MS data using unfractionated, fractionated plasma samples and abundant-protein depletion methods in terms of the numbers of detected peaks and reliability. Several statistical quality-control and quality-assessment techniques are proposed, including the Graeco-Latin square design for the sample allocation on a Protein chip, the use of the pairwise Pearson correlation coefficient as the similarity measure between the spectra in conjunction with multi-dimensional scaling (MDS) for graphically evaluating similarity of replicates and assessing outlier samples; and the use of the reliability ratio for evaluating reproducibility. Our results show that the number of peaks detected is similar among the three sample preparation technologies, and the use of the Sigma multi-removal kit does not improve peak detection. Fractionation of plasma samples introduces more experimental variability. The peaks detected using the unfractionated plasma samples have the highest reproducibility as determined by the reliability ratio.

Availability: Our algorithm for assessment of SELDI-TOF experiment quality is available at http://www.biostat.harvard.edu/~xlin

Contact: jharezla{at}hsph.harvard.edu

Associate Editor: Prof. Thomas Lengauer


Received on January 2, 2007; revised on June 1, 2007; accepted on June 26, 2007

Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.